bandiera
Prodotti
Casa /

YOKOGAWA

/Yokogawa ANT401-5E/CU1N S1 Optical ESB Bus Repeater Master Module
Yokogawa ANT401-5E/CU1N S1
Yokogawa ANT401-5E/CU1N S1
Yokogawa ANT401-5E/CU1N S1

Yokogawa ANT401-5E/CU1N S1 Optical ESB Bus Repeater Master Module

OPTICAL ESB BUS REPEATER MASTER MODULE

ANT401-5E/CU1N S1

Yokogawa ANT401-5E/CU1N S1 is a Yokogawa optical ESB bus repeater master module. It converts the ESB bus to an optical signal for a link of up to 5 km per hop, using a matching slave-side module.

PRODUCT TYPEOptical ESB Master
BASE MODELANT401
MAX DISTANCE5 km / hop
OPTICAL PORTLC
BRANDYokogawa
PRODUCT TYPEOptical ESB Bus Repeater Master Module
CONDITION / WARRANTYOriginal New · One-Year Warranty
VERIFICATIONPair the -5E variant with ANT502-□E, ANT502-□F or A2EN501-□1 slave hardware under the documented configuration. /CU1N provides a connector unit for the ESB bus; /CU1T is the separate terminator-equipped option.
REQUEST A QUOTE
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
PRODUCT INFORMATION● OFFICIAL YOKOGAWA REFERENCE
OPTICAL ESB BUS TRANSPORT

ANT401-5E/CU1N S1

OPTICAL ESB BUS REPEATER MASTER MODULE

5 km per hop · LC optical connector · Master side

PRODUCT ROLE
ANT401-5E/CU1N S1 is a Yokogawa optical ESB bus repeater master module. It converts the ESB bus to an optical signal for a link of up to 5 km per hop, using a matching slave-side module.
INSTALLATION CHECK
Pair the -5E variant with ANT502-□E, ANT502-□F or A2EN501-□1 slave hardware under the documented configuration. /CU1N provides a connector unit for the ESB bus; /CU1T is the separate terminator-equipped option.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.comWHATSAPP+86 153 5940 8275
OFFICIAL YOKOGAWA REFERENCE

Technical Specifications

VERIFY COMPLETE MODULE REFERENCE
ANT401-5E/CU1N S1

Engineering data at a glance

Click “+” to expand more specifications.

MAX HOP5 km
OPTICAL PORTLC
FIBER CORES2 cores
CURRENT0.5 A
Installation requirement
Use two-core single-mode optical fiber with LC connectors. Pair the -5E variant with ANT502-□E, ANT502-□F or A2EN501-□1 slave hardware under the documented configuration. In a dual-redundant arrangement, use matching module types on ESB bus 1 and bus 2.
ManufacturerYokogawa
ModelANT401-5E/CU1N S1
Product typeOptical ESB Bus Repeater Master Module
System familyCENTUM VP N-IO/FIO
FunctionESB bus optical transport
Maximum optical hop5 km
Current consumption0.5 A
Main-body weightApproximately 0.25 kg
Optical connectorLC; IEC 61754-20
Optical fiberQuartz single-mode fiber
Required fiber cores2
Permissible optical loss0 to 10 dB at 1.3 μm
Maximum chain hops2
TopologyChain and star connections
Bus connector option/CU1N: connector unit for ESB bus
Protection code-5: standard type with no explosion protection
Configuration codeE: basic type for the documented E/F optical pairing
Installable unitAFV30/AFV40/A2FV50/A2FV70, ANB10/ANB11 or ANT10U
Redundant installationPaired consecutive slots; ESB bus 1 in odd slot, bus 2 in even slot
Single configurationFit a dummy cover to the paired even-numbered slot
FAQ

ANT401-5E/CU1N S1 Optical ESB Bus Repeater Master Module FAQ

What does ANT401-5E/CU1N S1 do on the optical ESB link?+

ANT401-5E/CU1N S1 operates on the master side of an optical ESB connection. It converts electrical ESB bus communication to optical transport. The documented maximum is 5 km per optical hop.

Which optical fiber and connector are specified for ANT401-5E/CU1N S1?+

ANT401-5E/CU1N S1 uses an LC optical connector and two-core quartz single-mode fiber. Yokogawa specifies an optical loss allowance of 0 to 10 dB at 1.3 μm; the selected cable must also meet the 5 km hop limit.

What does /CU1N specify for ANT401-5E/CU1N S1?+

ANT401-5E/CU1N S1 includes the supplied /CU1N reference for an ESB bus connector unit. The separate /CU1T option is terminator-equipped, so the connector arrangement must follow the actual ESB wiring and endpoint position.

Which slave variants match ANT401-5E/CU1N S1?+

ANT401-5E/CU1N S1 belongs to the E/F optical pairing group. Pair the -5E variant with ANT502-□E, ANT502-□F or A2EN501-□1 slave hardware under the documented configuration. Do not select a different pairing group simply because its connector or family name looks similar.

Where can ANT401-5E/CU1N S1 be installed?+

ANT401-5E/CU1N S1 installs in the documented field-control, ESB node or ANT10U repeater-unit positions. Slot allocation differs for single and dual-redundant arrangements; use the unit-specific allocation table before fitting the module.

How is ANT401-5E/CU1N S1 arranged for dual redundancy?+

ANT401-5E/CU1N S1 uses consecutive paired slots in the documented redundant arrangement. Install ESB bus 1 in the odd-numbered slot and bus 2 in the even-numbered slot, and use the same module type on both buses.

What current consumption and weight are listed for ANT401-5E/CU1N S1?+

ANT401-5E/CU1N S1 is covered by Yokogawa specifications listing 0.5 A current consumption and approximately 0.25 kg for the main body. The main-body figure does not describe a complete node assembly or shipment packaging.

CONTACT PRODUCT SPECIALIST

Check ANT401-5E/CU1N S1 application details with Frida

Provide the ANT401-5E/CU1N S1 nameplate, installed unit, master/slave pairing, connector option, optical distance, required quantity and destination.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Official Hardware Specifications for
ANT401-5E/CU1N S1

Yokogawa GS 33J60F51-01EN covers ANT401 and ANT502, including the -50 and -5E configurations and the listed connector options. Refer to the matching optical-pairing notes when selecting hardware.

ANT401-5E/CU1N S1 official hardware reference

The official series PDF includes standard specifications, optical-fiber requirements, installation slots and model/suffix tables. It covers the base and ordering options shown here; the supplied S1 marking is retained without assigning undocumented electrical or compatibility differences.

VIEW OFFICIAL SERIES PDF

Contact to Get Support

Provide the ANT401-5E/CU1N S1 nameplate, installed unit, master/slave pairing, connector option, optical distance, required quantity and destination.

Reference: Yokogawa GS 33J60F51-01EN, standard specifications, installation and model/suffix tables. Match the master/slave configuration group and connector option; this is not an individual-unit certificate.

YOKOGAWA MODULE · MODEL IDENTIFICATION

How ANT401-5E/CU1N S1 Is Identified

Yokogawa GS 33J60F51-01EN defines the following literal model and option segments. S1 is retained as supplied, without assigning undocumented characteristic changes.

Yokogawa · BRAND
ANT401-5E/CU1N S1 Optical ESB Bus Repeater Master ModuleOFFICIAL MODEL REFERENCE
MODULE FAMILY

ANT401

Optical ESB Bus Repeater Master Module

PROTECTION TYPE

-5

Standard type with no explosion protection

CONFIGURATION

E

Basic type for E/F optical pairing

CONNECTOR OPTION

/CU1N

Connector unit for ESB bus

Model reference: Use the optical pairing group and bus connector option together. S1 remains in the complete supplied reference.
APPLICATION AREAS

Applications for ANT401-5E/CU1N S1

Distributed ESB Transport

Extends the electrical ESB bus through an optical link of up to 5 km per hop.

Master-Side Optical Link

Converts the ESB bus on the master side for connection to matching slave hardware.

PRODUCT REFERENCEANT401-5E/CU1N S1Yokogawa optical esb bus repeater master module
Chain Connection

Supports the documented chain topology, with a maximum of two optical hops.

Star Connection

Supports the documented star topology with the applicable field control and repeater hardware.

ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information+
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
✓Complete product and nameplate
✓Power supply and wiring connections
✓Installation and operating conditions
✓Indicator lights, alarms or error messages
✓Clear description of the fault
✓Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
lasciate un messaggio
Se sei interessato ai nostri prodotti e vuoi conoscere maggiori dettagli, lascia un messaggio qui, ti risponderemo il prima possibile.
  • PLC
  • DCS
  • STI
  • HMIS
prodotti correlati